UV Water Purification System Installation

Discover how to install a UV water purification system for chemical-free disinfection. This guide covers everything from setup to maintenance.

By
Kris Escueta
February 14, 2024

Installing a UV water purification system in your home can greatly improve the quality of water for drinking and use. UV systems provide effective and chemical-free disinfection, removing harmful microorganisms from water. This comprehensive DIY guide will walk you through everything you need to know to install a UV purification system yourself.

Benefits of UV Water Purification

  • Chemical-free disinfection
  • Kills 99.99% of microorganisms
  • Easy installation and maintenance
  • Cost-effective long term solution

UV light disrupts the DNA of microbes, rendering them unable to reproduce or infect, effectively disinfecting water. UV purification has many advantages over chemical treatments:

Safety

  • No chemical residuals or byproducts
  • Safe for people with chemical sensitivities

Convenience

  • Compact systems fit easily under sinks
  • No ongoing chemical refills needed

Cost Savings

  • Lower long term costs than bottled water -UV lamps last 12-24 months

With proper installation and maintenance, a UV system can provide safe, contaminant-free water for many years. This guide will cover everything you need to set up a UV system in your home.

Understanding UV Water Purification

UV stands for ultraviolet. UV purification uses short-wavelength ultraviolet light to disinfect water. The UV light damages the DNA and RNA of microorganisms like bacteria, viruses, and protozoa, preventing them from reproducing and infecting.

How UV Disinfection Works

UV systems are placed in-line to treat all water flowing through. As water passes through, a UV lamp emits a UV-C light beam that penetrates organisms and disrupts their DNA. This renders them unable to reproduce or infect while leaving the water free of any chemical residuals.

Microorganisms UV Light Can Destroy

UV effectively destroys many disease-causing microbes found in water:

  • Bacteria: E. coli, Vibrio cholera, Salmonella, Shigella
  • Viruses: Rotavirus, noroviruses, hepatitis A and E virus
  • Protozoa: Cryptosporidium, Giardia lamblia

By installing a UV system, you can protect your household from waterborne pathogens.

Pre-Installation Preparation

Proper planning and preparation ensure smooth installation and optimal performance of the UV system.

Water Testing

Test your water to identify any existing contaminants, particulates, hardness and iron levels. This determines if any pre-filtration is needed to prevent interference and fouling.

Consult a water testing lab for detailed results. Basic tests to run:

  • Bacteria levels
  • Turbidity
  • Total dissolved solids (TDS)
  • Iron, manganese and sulfur

Location Selection

Choose an appropriate location to install the UV unit. Ideal installation points:

Under the sink

  • Convenient for homes, offices, RVs
  • Easy access for maintenance

Main water line

  • Treats all incoming water
  • Place after other conditioning systems

Ensure the location:

  • Has adequate room for the sized unit
  • Allows straight pipe sections before and after the chamber
  • Is easily accessible for maintenance
  • Has an electrical outlet nearby for powered systems

Water Flow and Pressure

UV systems require an optimal water flow at minimum pressure to ensure sufficient exposure.

Water Flow

The flow rate must match the approved operating flow rate for the UV unit size. If the home flow rate is higher, install a flow-restricting valve before the UV system.

Water Pressure

Verify water pressure is above the minimum psi required by the manufacturer, using a gauge. If pressure is inadequate, install a booster pump system before the UV unit.

Step-by-Step Installation Guide

Follow this comprehensive 10-step guide for proper do-it-yourself installation.

Step 1: Gather the Required Materials

Assemble all the necessary materials before starting:

UV system and components:

  • UV chamber
  • UV lamp
  • Reactor cap
  • Ballast or electronic controller
  • Power supply

Tools & Parts:

  • Sizing tool for cutting pipes
  • PVC glue/cleaner and Teflon tape
  • Screwdriver and wrenches
  • Eye protection
  • Tubes/hoses to construct bypasses

Pre-filtering:

  • Sediment pre-filter housing
  • Activated carbon filter cartridges *Optional

Step 2: Turn Off Water Supply

Turn off main water supply via shut off valve. Open the highest and lowest faucets to depressurize pipes. Check all fixtures to ensure water is completely shut off. Turn off any electricity near the installation site.

Step 3: Install Bypass Setup *Optional

Constructing a bypass allows isolating the UV system for maintenance without disrupting water flow.

Parts needed:

  • 3 PVCs or ball valves
  • 2 short pipe segments
  • 4 elbow joints

Procedure:

  1. Cut out a section of the main pipe.
  2. Attach bypass pipes parallel to cut section.
  3. Connect elbow joints from the stub pipes to valves on bypass routes.

Step 4: Install Sediment Pre-Filter

Sediment filters to remove particulates that could shield microbes or absorb UV light.

Procedure:

  1. Shut off main cold water line.
  2. Cut the pipe at the planned location.
  3. Install a 20″ sediment filter housing using couplings.
  4. Attach filter cartridge and seal the housing.
  5. Slowly turn water back on and check for leaks.

Step 5: Mount the UV Chamber

Properly secure the sterilization chamber vertically before connecting.

Considerations:

  1. Position straight pipe sections before and after the chamber.
  2. Ensure 2″ gap above chamber for lamp changes.
  3. Allow room for electrical and water connections.

Procedure:

  • Mark and mount chamber brackets securely to the wall.
  • Carefully hang chamber device onto the wall brackets.

Step 6: Install Optional Carbon Filter

An activated carbon filter removes chlorine, tastes and odors after UV treatment. This maximizes water quality.

Procedure:

  1. Shut off cold water supply after UV chamber.
  2. Cut in a carbon filter housing at chosen location.
  3. Insert filter cartridge then seal the housing.

Step 7: Connect UV System

With chamber mounted, connect water supply lines.

Considerations:

  1. Verify direction of flow matches arrow on chamber.
  2. Shut off valve lets you isolate the UV system if needed.

Procedure:

  1. Shut off water at extended lines from house supply.
  2. Use couplings to connect pipes to the inlet and outlet.
  3. Install a shutoff valve after the UV chamber outlet.
  4. Slowly turn on water supply and check for leaks.

Step 8: Install Quartz Sleeve and UV Lamp

The quartz sleeve protects the germicidal UV lamp inside the chamber.

Procedure:

  1. Unscrew the top of the UV chamber.
  2. Carefully place quartz sleeve tube inside.
  3. Insert UV lamp into the quartz sleeve.
  4. Replace chamber top and hand-tighten.

Step 9: Connect Ballast Controller

The ballast provides controlled power to operate the UV lamp.

Considerations:

  1. Position ballast vertically near the chamber.
  2. Allow slack in cables for lamp removal.
  3. Ballast is NOT waterproof – prevent moisture exposure.

Procedure:

  1. Bolt the ballast vertically to a secure surface.
  2. Connect lamp wires to the ballast properly.

Step 10: Test and Commission System

With installation complete, test to ensure full functionality before use.

Procedure:

  1. Turn on water supply and check all connections for leaks.
  2. Plug ballast power cable into a GFCI outlet to turn on UV lamp.
  3. Open main faucet and verify water flows through entire assembly without issues or leaks.

The UV water purification system is now fully operational! Flush water lines for 5 minutes before first use.

Post-Installation Maintenance

Regular maintenance keeps a UV system working optimally for the longest lifespan possible.

Change UV Lamp Annually

UV lamps effectively treat water for 9000 hours of continuous use. Mark your calendar and replace bulbs every 9-12 months.

Procedure:

  1. Shut off water flow and disconnect power.
  2. Drain all water from the chamber.
  3. Unscrew the UV chamber lid.
  4. Remove old UV lamp safely. DO NOT touch glass.
  5. Insert new lamp, taking care not to touch bulb surface.
  6. Replace lid, reconnect to ballast and test.

Clean Quartz Sleeve

Mineral deposits or sediment can coat the sleeve, reducing UV penetration. Clean if flow rate seems reduced.

Cleaning Procedure:

  1. Shut off water flow and drain all water from chamber.
  2. Disconnect inlet and outlet fittings.
  3. Gently remove quartz sleeve tube from chamber.
  4. Clean tube carefully with scale remover/weak acid solution using soft cloth.
  5. Rinse sleeve thoroughly before replacing it into chamber.

Annual System Validation

Test system efficacy annually via bioassay validation to ensure optimum microorganism inactivation. Contact the manufacturer for kits.

Summary of Maintenance Schedule

Maintenance TaskFrequency
Lamp ReplacementEvery 9-12 months
Quartz Sleeve CleaningAs needed
Bioassay ValidationAnnually
Water Quality TestingAnnually

Taking care of your UV system with regular maintenance ensures ongoing safety and peace of mind.

Conclusion

Installing a UV water purification system allows you to take water quality into your own hands, leveraging UV’s effective and chemical-free disinfection powers. While the installation process requires precision, it is a doable DIY project for most homeowners.

This guide provided you with comprehensive instructions for proper installation and maintenance to maximize performance and lifespan of your UV system. Be sure to adhere to all manufacturer recommendations.

Drinking pure, contaminant-free water is an investment in health and well-being for your family. Take proactive control of your home’s water safety with UV disinfection. Your UV water purification system will provide reliable protection against waterborne diseases for years to come.